HUAWEI NetEngine40E Universal ServiceRouter
Hardware Description
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Enhanced command-line interface
SNMP and MIB support
Long-term ambient temperature: 0°C to 45°C ( 32°F to 113°F )
Short-term ambient temperature: -5°C to +55°C ( 23°F to 131°F )
Long-term relative humidity: 5% to 85%
Short-term relative humidity: 0% to 95%
Storage temperature: -40°C to +70°C ( -40°F to 158°F )
Storage humidity: 0% to 95%
6.6.2 24-Port 100/1000Base-SFP Flexible Card(P100,Occupy two
sub-slots)
Overview
Figure 6-15 shows the appearance of the 24-Port 100/1000Base-SFP FPIC.
GE optical module, providing features of GE optical interfaces.
FE optical module, providing features of FE optical interfaces.
Electrical interface SFP module, providing features of the 1000M electrical interfaces.
Intermixing of the preceding modules.
On a 24-port 100/1000Base-SFP flexible card, electrical interface SFP modules can only be installed in
interfaces of the odd numbers.
If optic fiber on a sub-card is hard to be inserted and removed because the sub-card is fully configured,
use a fiber interface clamp.
If the indicator switching button is sheltered by cables, user a tool such as a fiber interface clamp to help
push the button.
Figure 6-15 Appearance of the 24-Port 100/1000Base-SFP FPIC