HUAWEI NetEngine40E Universal ServiceRouter
Hardware Description
3 NE40E-X8 Chassis Overview
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
54
3.4 Switching Network
This section describes the functions of the switch fabric unit.
The 200G switch fabric unit cannot be used together with 40G switch fabric unit for long-term
working, and can be used together only for short-term operation during upgrade.
3.4.1 Introduction to the Switching Network
This section describes the principle of the SFU.
The switching network responsible for switching data between LPUs is a key component of
the NE40E. The NE40E uses the switching chips developed by Huawei and
Memory-Crossbar-Memory (M-C-M) to provide a three-level switching mode. Level-1 and
level-3 switching adopts the shared-memory model and is performed on LPUs; level-2
switching adopts the Crossbar model and is performed on an SFU. Figure 3-14 shows the
switching network of the NE40E.
The level-1 switching chip on one LPU is fully connected to all the level-2 switching chips on
the SFUs. The level-2 switching chips on the SFUs are also fully connected to the level-3
switching chip on another LPU. In addition, the level-2 crossbar switching chips work in load
balancing mode across multiple switching planes. The entire switching network is unblocked.
The following describes how data packets are transmitted across the switching network.
1. Data packets enter an LPU through physical interfaces and are fragmented into cells of a
fixed length. These cells are then sent to the level-1 switching chips. After being
buffered and scheduled, the cells enter the crossbar switching chips on the SFU. The
level-1 switching chip on an LPU is fully connected with all of the level-2 switching
chips on SFUs. As a result, the same number of cells can be distributed to each level-2
switching plane. This implements load balancing across switching planes and facilitates
fault tolerance.
2. After the cells reach the crossbar switching chips, the crossbar switching chips schedule
the cells to the corresponding outbound interfaces according to the destination interfaces
of the data packets. The cells are then sent to the level-3 switching chips on another LPU.
At this point, the switching of the cells by the level-2 switching chips is completed.
3. After the cells reach the level-3 switching chips on another LPU, the system searches for
the destination interfaces. Once found, the cells are reassembled and sent out through
physical interfaces. At this point, the switching of the data packets is completed.

Table of Contents

Other manuals for Huawei NetEngine40E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei NetEngine40E and is the answer not in the manual?

Huawei NetEngine40E Specifications

General IconGeneral
BrandHuawei
ModelNetEngine40E
CategoryNetwork Router
LanguageEnglish

Related product manuals