Observe the PSU indicators to check the PSU operating status. For details about
the indicators, see 2.4 Indicators and Buttons.
Procedure
Step 1 Wear an ESD wrist strap. For details, see 1 Safety Instructions.
Step 2 Determine the cabinet number and chassis number of the server, and label its
panel to prevent misoperations.
Step 3 Hold down the spring below the power cable using a
at-head screwdriver to
eject the power cable. See Figure 7-13.
Figure 7-13 Removing power cables
Step 4 Hold down the latch on the PSU, and partially pull out the PSU by holding its
handle. See (1) in Figure 7-14.
RH2288H V3 Server
User Guide 7 Replacing Parts
Issue 46 (2022-12-28) Copyright © Huawei Technologies Co., Ltd. 160

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei RH2288H V3 and is the answer not in the manual?

Huawei RH2288H V3 Specifications

General IconGeneral
Form Factor2U Rack
ProcessorIntel Xeon E5-2600 v3/v4 series
MemoryUp to 1.5 TB, 24 DDR4 DIMM slots
StorageSupports up to 12 x 3.5-inch or 25 x 2.5-inch SAS/SATA HDDs/SSDs
RAID SupportRAID 0, 1, 10, 5, 50
Network2 or 4 x GE ports
Power Supply2 x hot-swappable PSUs
ManagementiBMC (Intelligent Baseboard Management Controller)
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi