Table 5. SPCN Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
1011 1521 Power supply 2 fault 1. Primary I/O drawer power supply 2
Location: U0.1-V2
2. Primary I/O backplane
Location: U0.1-P1
1011 1522 Power supply 2 non-power fault 1. Primary I/O drawer power supply 2
Location: U0.1-V2
2. Primary I/O backplane
Location: U0.1-P1
1011 1523 Power supply 2 domain fault 1. Primary I/O drawer power supply 2
Location: U0.1-V2
2. Primary I/O backplane
Location: U0.1-P1
1011 1524 Power supply 2 cooling fault 1. Primary I/O drawer power supply 2
Location: U0.1-V2
2. Primary I/O backplane
Location: U0.1-P1
1011 1526 Power supply 2 missing I/O drawer power supply 2
Location: U0.1-V2
1011 1611 CEC regulator 1 fault Regulator card
Location: U1.1-P1-V1
1011 1612 CEC regulator 1 non-power fault Regulator card
Location: U1.1-P1-V1
1011 1613 CEC regulator 1 domain fault Regulator card
Location: U1.1-P1-V1
1011 1621 CEC regulator 2 fault Regulator card
Location: U1.1-P1-V1
1011 1622 CEC regulator 2 non-power fault Regulator card
Location: U1.1-P1-V1
1011 1623 CEC regulator 2 domain fault Regulator card
Location: U1.1-P1-V1
1011 1631 CEC regulator 3 fault RIO expander card
Location: U1.1-P1.1
1011 1632 CEC regulator 3 non-power fault 1. RIO expander card
Location: U1.1-P1.1
2. Primary I/O backplane
Location: U0.1-P1
1011 1633 CEC regulator 3 domain fault RIO expander card
Location: U1.1-P1.1
1011 1910 Power supply 1 power source failure 1. Check input to power supply 1
Location: U1.1-V1
2. CEC drawer power supply 1
Location: U1.1-V1
3. Primary I/O backplane
Location: U0.1-P1
1011 1911 Power supply 1 fault 1. CEC drawer power supply 1
Location: U1.1-V1
2. Primary I/O backplane
Location: U0.1-P1
166 Service Guide