If Memory Repeat Gard is disabled, DIMMs that are in the deconfigured by system state will be
reconfigured. These reconfigured DIMMs are then tested during the boot process, and if they pass, they
remain online. If they fail the boot testing, they are deconfigured even though Memory Repeat Gard is
disabled.
The failure history of each DIMM is retained. If a DIMM with a history of failures is brought back online by
disabling Repeat Gard, it remains online if it passes testing during the boot process. However, if Repeat
Gard is enabled, the DIMM is taken offline again because of its history of failures.
Memory Riser Card 1 Memory DIMM Locations for Service Processor
Menus
31: 11.46
29: 11.38
27: 11.30
25: 11.22
23: 11.44
21: 11.36
19: 11.28
17: 11.20
15: 11.42
13: 11.34
11: 11.26
9: 11.18
7: 11.40
5: 11.32
3: 11.24
1: 11.16
32: 11.47
30: 11.39
28: 11.31
26: 11.23
24: 11.45
22: 11.37
20: 11.29
18: 11.21
16: 11.43
14: 11.35
12: 11.27
10: 11.19
8: 11.41
6: 11.33
4: 11.25
2: 11.17
376 Service Guide

Table of Contents

Other manuals for IBM RS/6000 Enterprise Server M80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM RS/6000 Enterprise Server M80 and is the answer not in the manual?

IBM RS/6000 Enterprise Server M80 Specifications

General IconGeneral
BrandIBM
ModelRS/6000 Enterprise Server M80
CategoryServer
LanguageEnglish

Related product manuals