SPCN Error Codes
Attention: If a power supply or fan is hot-swapped, wait five minutes, then recheck the AIX error log. If
the system has to be shut down to replace a power supply or fan, reboot the system, wait five minutes
after the AIX login prompt appears, then recheck the AIX error log. If the detailed information for the most
recent error with the same identifier indicates that the original problem has not been fixed by performing
the first action in the action column, continue with the next action in the action column.
Attention: If you replace FRUs or perform an action and the problem is still not corrected, go to “MAP
1540: Minimum Configuration” on page 110 unless otherwise indicated in the tables.
If you replace FRUs and the problem is corrected, go to MAP 0410: Repair Checkout in RS/6000 and
Eserver pSeries Diagnostic Information for Multiple Bus Systems.
Note: Do not shut down the system if the FRU was replaced by hot swap.
Table 5. SPCN Error Codes
Error Code Description Action/
Possible Failing FRU
1011 00AC ac loss or brownout detected Information message
1011 00EF Room emergency power off detected Information message
1011 1510 Power supply 1 power source failure 1. Check input power to power supply 1
Location: U0.1-V1
2. Primary I/O drawer power supply 1
Location: U0.1-V1
3. Primary I/O backplane
Location: U0.1-P1
1011 1511 Power supply 1 fault 1. Primary I/O drawer power supply 1
Location: U0.1-V1
2. Primary I/O backplane
Location: U0.1-P1
1011 1512 Power supply 1 non-power fault 1. Primary I/O drawer power supply 1
Location: U0.1-V1
2. Primary I/O backplane
Location: U0.1-P1
1011 1513 Power supply 1 domain fault 1. Primary I/O drawer power supply 1
Location: U0.1-V1
2. Primary I/O backplane
Location: U0.1-P1
1011 1514 Power supply 1 cooling fault 1. Primary I/O drawer power supply 1
Location: U0.1-V1
2. Primary I/O backplane
Location: U0.1-P1
1011 1516 Swapped power supply and cooling unit
or
power supply 1 missing
1. Verify correct installation of power supply
and cooling unit
Location: U0.1-V1
2. Primary I/O power supply 1
Location: U0.1-V1
1011 1520 Power supply 2 power source failure 1. Check input power to Power Supply 2
Location: U0.1-V2
2. Primary I/O drawer power supply 2
Location: U0.1-V2
3. Primary I/O backplane
Location: U0.1-P1
Chapter 5. Error Code to FRU Index 165

Table of Contents

Other manuals for IBM RS/6000 Enterprise Server M80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM RS/6000 Enterprise Server M80 and is the answer not in the manual?

IBM RS/6000 Enterprise Server M80 Specifications

General IconGeneral
BrandIBM
ModelRS/6000 Enterprise Server M80
CategoryServer
LanguageEnglish

Related product manuals