4 Technische gegevens
4.1 Elektrische gegevens
KACO
bluepla-
net 3.0
TL3 M2
WM OD
IIG0
KACO
bluepla-
net 4.0
TL3 M2
WM OD
IIG0
KACO
bluepla-
net 5.0
TL3 M2
WM OD
IIG0
KACO
bluepla-
net 6.5
TL3 M2
WM OD
IIG0
KACO
bluepla-
net 7.5
TL3 M2
WM OD
IIG0
KACO
bluepla-
net 8.6
TL3 M2
WM OD
IIG0 -
3TL301
KACO
bluepla-
net 9.0
TL3 M2
WM OD
IIG0
KACO
bluepla-
net 10.0
TL3 M2
WM OD
IIG0 -
3TL301
DC ingangsgrootheden Ingangsgrootheden (DC)
Aanbevolen generator-vermo-
gensbereik
3,6 kW 4,8 kW 6 kW 7,8 kW 9 kW 10,3 kW 10,8 kW 12 kW
MPP-Bereich@Pnom 200-800 V
240-800
V
310-800
V
350-800
V
403-800
V
420-800
V
470-800
V
Werkbereik 200 V -950 V
Nominale spanning 653 V
Startspanning 250 V
Nullastspanning 1000 V
Ingangsstroom max. 2x11 A
Aantal strings 1
Aantal MPP-regelaars 2
max. kortsluitstroom (ISC max.) 2x16 A
Ingangsbron terugvoerstroom 0 A
Beveiliging tegen ompoling ja
Stringzekering nee
Overspanningsbeveiliging DC geïntegreerd
KACO
bluepla-
net 3.0
TL3 M2
WM OD
IIG0
KACO
bluepla-
net 4.0
TL3 M2
WM OD
IIG0
KACO
bluepla-
net 5.0
TL3 M2
WM OD
IIG0
KACO
bluepla-
net 6.5
TL3 M2
WM OD
IIG0
KACO
bluepla-
net 7.5
TL3 M2
WM OD
IIG0
KACO
bluepla-
net 8.6
TL3 M2
WM OD
IIG0 -
3TL301
KACO
bluepla-
net 9.0
TL3 M2
WM OD
IIG0
KACO
bluepla-
net 10.0
TL3 M2
WM OD
IIG0 -
3TL301
AC uitgangsgrootheden Uitgangsgrootheden (AC)
Nominaal vermogen 3 kVA 4 kVA 5 kVA 6,5 kVA 7,5 kVA 8,6 kVA 9 kVA 10 kVA
Nominale spanning
220 / 380 V [3/N/PE];
230 / 400 V [3/N/PE];
240 / 415 V [3/N/PE]
Spanningsbereik: continu bedrijf 305 V - 480 V [Ph-Ph]
Nominale stroom
3x 4,20 A
[@415V];
3x 4,35 A
[@400V];
3x 4,60 A
[@380V]
3x 5,60 A
[@415V];
3x 5,80 A
[@400V];
3x 6,10 A
[@380V]
3x 7,00 A
[@415V];
3x 7,25 A
[@400V];
3x 7,60 A
[@380V]
3x 9,10 A
[@415V];
3x 9,50 A
[@400V];
3x 9,90 A
[@380V]
3x 10,50
A
[@415V];
3x 10,90
A
[@400V];
3x 11,40
A
[@380V]
3x 12,00
A
[@415V];
3x 12,50
A
[@400V];
3x 13,10
A
[@380V]
3x 12,60
A
[@415V];
3x 13,00
A
[@400V];
3x 13,70
A
[@380V]
3x 14,95
A
[@415V];
3x 14,50
A
[@400V];
3x 15,20
A
[@380V]
max. continue stroom 3x4,8 A 3x6,4 A 3x8,0 A 3x10,5 A 3x12,0 A 3x13,2 A 3x14,0 A 3x15,5 A
Bijdrage aan stootkortsluitstroom
ip
34,96 A 35 A 41 A 35 A 41 A
KACO blueplanet 3.0 TL3 KACO blueplanet 4.0 TL3 KACO blueplanet 5.0 TL3 KACO blueplanet 6.5 TL3 KACO
blueplanet 7.5 TL3 KACO blueplanet 8.6 TL3 KACO blueplanet 9.0 TL3 KACO blueplanet 10.0 TL3
Bladzijde 182
ENDEFRESPTITNL

Table of Contents

Other manuals for Kaco blueplanet 3.0 TL3 M2 WM OD IIG0

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kaco blueplanet 3.0 TL3 M2 WM OD IIG0 and is the answer not in the manual?

Kaco blueplanet 3.0 TL3 M2 WM OD IIG0 Specifications

General IconGeneral
BrandKaco
Modelblueplanet 3.0 TL3 M2 WM OD IIG0
CategoryInverter
LanguageEnglish

Related product manuals