S.8
ELECTRICAL
SYSTEM
G1700G1800·G1900·G2000
WSM.l0831
COOLANT
TEMPERATURE SENSOR
Item
I Factory Specification
Allowable
limit
Coolant Temperature Sensor Resistance
Approx. 51.9
n
at
80°C (176
OF)
Approx. 24.2 n
at
105°C (221°F)
-
FUEL PUMP
I
Fuel
Pump Resistance
Approx.
20 n
FUEL
lEVEL
SENSOR
Fuel
level Sensor Resistance
(Float
at
Uppermost Position)
Approx.
3 Q
-
Fuel
Level Sensor Resistance
(Float
at
Lowermost Position)
Approx.
110 U
-
COOLANT
TEMPERATURE SWITCH
Coolant Temperature Switch Resistance
Infinity
[I
ess
than
120°C ]
(248
OF)
Continuity
~
120
to
126°C J
(248
to
259
OF)
-
-
CHECKING, DISASSEMBLING
AND
SERVICING
A
CAUTION
To
avoid accidental short circuit. be sure
to
attach
the
positive
cable
to
the
positive
terminal
before
the
ground cable
is
attached
to
the
negative
terminal.
[1]
BAlTERY
CHECKING
Battery
Voltage
1.
Stop
the
engine
and
turn
the
main switch
off.
2.
Connect
the
COM
(-)
lead
of
the
voltmeter
to
the
battery's
negative
terminal
post
and
the
positive
(+)
lead
to
the
positive
terminal
post, and measure
the
battery
voltage.
3.
If
the
battery
voltage
is
less
than
the
factory
specification,
check
the
battery
specific
gravity
and recharge.
Battery
voltage'
.
Factory spec.
More
than
12 V