S.8
ELECTRICAL
SYSTEM
G1700-G1800'G1900-G2000
WSM,10830
SERVICING
(1)
Starter
[G1700·G1800.G1900]
0302Pl58
0302P160
Solenoid Switch
1) Pull-in Coil
(Attraction
Test)
1.
Connect a
jumper
lead
from
the
ST
terminal
to
the
positive
terminal
of
6 V battery.
2.
Connect a
jumper
lead
between
the
C
terminal
and
negative
terminal
of
6 V battery.
3.
If
the
plunger
is
attracted
strongly,
the
pull-in
coil
is
good;
if
not,
it
is
defective.
2}
Holding
Coil (Retention Test)
1.
Connect a
jumper
lead
from
the
ST
terminal
to
the
positive
terminal
of
6 V battery.
2.
Connect a
jumper
lead
between
the
solenoid
switch
body
and negative
terminal
of
6 V
battery,
push
the
plunger
in
by
hand, and then release
it.
3.
If
the
plunger
stays attracted,
the
holding
coil
is
good;
if
not,
it
is
defective.
3)
Plunger Return Stroke
1.
Apply
the
rated
voltage
(approx. 12 V) between C
terminal
and solenoid switch body.
Push
the
plunger
in
by
hand, and
then
release
the
hand.
2.
If
the
plunger
returns
immediately,
it
is
good;
if
not,
it
is
defective_
Armature
Coil
1.
Check
the
continuity
across
the
commutator
and
armature
shaft
with
an
ohmmeter.
2.
If
it
conducts. replace
the
armature.