EasyManuals Logo
Home>Lenze>Inverter>I51AE175B

Lenze I51AE175B User Manual

Lenze I51AE175B
487 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #130 background imageLoading...
Page #130 background image
8.3.1 V/f voltage boost
The parameterisable voltage boost makes it possible to improve the starng performance for
applicaons requiring a high starng torque.
Precondions
The funcon is only eecve in the motor control type "V/f characterisc control (VFC open
loop)".
Details
In 0x2B12:001 (P316.01), a permanent voltage boost can be set.
In 0x2B12:002 (P316.02), an addional voltage boost can be set for acceleraon processes
only.
Reference for the percentage seng of the voltage boost is the base voltage 0x2B01:001
(P303.01).
0x2540 001:
0x2916
0
[%]
[Hz]
0
0x2B01 001:
0x2B01 002:
100
0x2B12 001:
0x2B12 002:
0x2B01 002:
2
0x2B12 001:
2
Parameter Name / value range / [default seng] Info
0x2B12:001
(P316.01)
Fixed boost
(Fixed V/f boost)
0.0 ... [2.5]* ... 20.0 %
* Default seng depending on the size.
Fixed (constant) voltage boost for V/f characterisc control without feed-
back.
100 % ≡ V/f base voltage 0x2B01:001 (P303.01)
For the purpose of opmising the starng performance for applica-
ons requiring a high starng torque.
0x2B12:002
(P316.02)
V/f voltage boost: Boost at acceleraon
(V/f boosts: Dynam. V/f boost)
0.0 ... [0.0] ... 20.0 %
Addional voltage boost for V/f characterisc control without feedback.
100 % ≡ V/f base voltage 0x2B01:001 (P303.01)
This voltage boost is only acve while the motor is accelerated. It then
acts in addion to the xed voltage boost set in 0x2B12:001
(P316.01).
0x2B01:001
(P303.01)
V/f shape data: Base voltage
(V/f shape data: Base voltage)
0 ... [230]* ... 5000 V
* Default seng depending on the size.
Base voltage and base frequency dene the V/f rao and thus the gradi-
ent of the V/f characterisc.
The V/f base voltage is usually set to the rated motor voltage
0x2C01:007 (P320.07).
The V/f base frequency is usually set to the rated motor frequency
0x2C01:005 (P320.05).
0x2B01:002
(P303.02)
V/f shape data: Base frequency
(V/f shape data: Base frequency)
Device for 50-Hz mains: 0 ... [50]* ... 1500 Hz
Device for 60-Hz mains: 0 ... [60]* ... 1500 Hz
* Default seng depending on the size.
Motor control
Opmisaon of motor control
V/f voltage boost
130

Table of Contents

Other manuals for Lenze I51AE175B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze I51AE175B and is the answer not in the manual?

Lenze I51AE175B Specifications

General IconGeneral
BrandLenze
ModelI51AE175B
CategoryInverter
LanguageEnglish

Related product manuals