13.3.7 Setpoint source segment setpoints
The four funcons "Acvate segment setpoint (bit 0)" ... " Acvate segment setpoint´(bit 3)"
enable a setpoint change-over to a segment setpoint parameterised for the "sequencer" func-
on during normal operaon.
Precondions
A setpoint change-over to the respecve segment setpoint is only eected if no setpoint
source with a higher priority has been selected. 4Priority of the setpoint sources ^ 367
Details
A segment setpoint is selected in a binary-coded fashion via the triggers assigned to the four
funcons "Acvate segment setpoint (bit 0)" ... " Acvate segment setpoint´(bit 3)" in compli-
ance with the following truth table:
Acvate segment setpoint Selecon
Bit 3
0x2631:029
(P400.29)
Bit 2
0x2631:028
(P400.28)
Bit 1
0x2631:027
(P400.27)
Bit 0
0x2631:026
(P400.26)
Segment Frequency setpoint PID setpoint Torque setpoint
FALSE FALSE FALSE FALSE No segment setpoint selected
FALSE FALSE FALSE TRUE 1 0x4026:001 (P801.01) 0x4026:006 (P801.06) 0x4026:007 (P801.07)
FALSE FALSE TRUE FALSE 2 0x4027:001 (P802.01) 0x4027:006 (P802.06) 0x4027:007 (P802.07)
FALSE FALSE TRUE TRUE 3 0x4028:001 (P803.01) 0x4028:006 (P803.06) 0x4028:007 (P803.07)
FALSE TRUE FALSE FALSE 4 0x4029:001 (P804.01) 0x4029:006 (P804.06) 0x4029:007 (P804.07)
FALSE TRUE FALSE TRUE 5 0x402A:001 (P805.01) 0x402A:006 (P805.06) 0x402A:007 (P805.07)
FALSE TRUE TRUE FALSE 6 0x402B:001 (P806.01) 0x402B:006 (P806.06) 0x402B:007 (P806.07)
FALSE TRUE TRUE TRUE 7 0x402C:001 (P807.01) 0x402C:006 (P807.06) 0x402C:007 (P807.07)
TRUE FALSE FALSE FALSE 8 0x402D:001 (P808.01) 0x402D:006 (P808.06) 0x402D:007 (P808.07)
TRUE FALSE FALSE TRUE Invalid selecon
...
TRUE TRUE TRUE TRUE
Parameter Name / value range / [default seng] Info
0x2631:026
(P400.26)
Funcon list: Acvate segment setpoint (bit 0)
(Funcon list: Setp: Segment b0)
From version 03.00
For further possible sengs, see parameter
0x2631:001 (P400.01). ^ 351
Assignment of a trigger for the "Acvate segment setpoint (bit 0)" func-
on.
Selecon bit with the valency 20 for the bit-coded selecon and acva-
on of a parameterised segment setpoint.
Trigger = FALSE: selecon bit = "0".
Trigger = TRUE: selecon bit = "1".
Notes:
During normal operaon (no acve sequence), this funcon serves to
acvate the setpoint of a segment (instead of an enre sequence in
the sequencer operaon).
This funcon is not intended for the use in the sequencer operaon.
0 Not connected
0x2631:027
(P400.27)
Funcon list: Acvate segment setpoint (bit 1)
(Funcon list: Setp: Segment b1)
From version 03.00
For further possible sengs, see parameter
0x2631:001 (P400.01). ^ 351
Assignment of a trigger for the "Acvate segment setpoint (bit 1)" func-
on.
Selecon bit with the valency 2
1
for the bit-coded selecon and acva-
on of a parameterised segment setpoint.
Trigger = FALSE: selecon bit = "0".
Trigger = TRUE: selecon bit = "1".
Notes:
During normal operaon (no acve sequence), this funcon serves to
acvate the setpoint of a segment (instead of an enre sequence in
the sequencer operaon).
This funcon is not intended for the use in the sequencer operaon.
0 Not connected
Flexible I/O conguraon
Setpoint change-over
Setpoint source segment setpoints
382

Table of Contents