Parameter Name / value range / [default seng] Info
0x2448:003 WLAN status: Rx frame counter
Read only
From version 02.00
Display of the number of request received via WLAN.
0x2448:004 WLAN status: Error stascs
Read only
From version 02.00
Display of the quality of the WLAN connecon. A display value > 0 indi-
cates communicaon problemsn.
0x2449 WLAN error
Read only
From version 02.00
Bit coded display of WLAN errors.
Bit 2 WLAN error
Bit 3 Memory problem
Bit 4 WLAN connecon problem
Bit 7 WLAN o
Bit 9 Client mode o
Bit 12 TCP/IP conguraon error
Bit 13 Password length
Bit 14 Access denied
Related topics
4Wireless LAN (WLAN) ^ 257
6.2.7 Setpoint diagnosc
The following parameters show the current setpoints of dierent setpoint sources.
Parameter Name / value range / [default seng] Info
0x282B:007 Inverter diagnoscs: Default frequency setpoint
Read only: x.x Hz
From version 03.00
Display of the frequency setpoint of the standard setpoint source set in
0x2860:001 (P201.01).
0x282B:008 Inverter diagnoscs: Preset frequency setpoint
Read only: x.x Hz
From version 03.00
Display of the preset frequency setpoint selected via the four funcons
"Acvate preset (bit 0)" ... " Acvate preset (bit 3)".
4Setpoint source of preset setpoints ^ 373
0x282B:009 Inverter diagnoscs: Actual frequency setpoint
Read only: x.x Hz
From version 03.00
Display of the currently selected frequency setpoint that is internally
transferred to the motor control.
0x282B:010 Inverter diagnoscs: Default PID setpoint
Read only: x.xx PID unit
From version 03.00
Display of the PID control value of the standard setpoint source set in
0x2860:002 (P201.02).
0x282B:011 Inverter diagnoscs: Preset PID setpoint
Read only: x.xx PID unit
From version 03.00
Display of the preset PID setpoint selected via the four funcons "Ac-
vate preset (bit 0)" ... " Acvate preset (bit 3)".
4Setpoint source of preset setpoints ^ 373
0x282B:012 Inverter diagnoscs: Default torque setpoint
Read only: x.x %
From version 03.00
Display of the torque setpoint of the standard setpoint source set in
0x2860:003 (P201.03).
100 % ≡ Motor rated torque 0x6076 (P325.00)
0x282B:013 Inverter diagnoscs: Preset torque setpoint
Read only: x.x %
From version 03.00
Display of the preset torque setpoint selected via the four funcons
"Acvate preset (bit 0)" ... " Acvate preset (bit 3)".
4Setpoint source of preset setpoints ^ 373
0x2948:001 Actual torque setpoint
Read only: x.x %
From version 03.00
Display of the currently selected torque setpoint that is internally trans-
ferred to the motor control.
100 % ≡ Motor rated torque 0x6076 (P325.00)
0x2DAE:010 Sequencer diagnoscs: Frequency setpoint
Read only: x.x Hz
From version 03.00
Display of the current frequency setpoint of the "sequencer" funcon.
4Sequencer ^ 325
0x2DAE:011 Sequencer diagnoscs: PID setpoint
Read only: x.xx PID unit
From version 03.00
Display of the current PID control value of the "sequencer" funcon.
4Sequencer ^ 325
0x2DAE:012 Sequencer diagnoscs: Torque setpoint
Read only: x.x %
From version 03.00
Display of the current torque setpoint of the "sequencer" funcon.
100 % ≡ Motor rated torque 0x6076 (P325.00)
4Sequencer ^ 325
0x4009:004 MOP values saved: Frequency setpoint
Read only: x.x Hz
Display of the last MOP value saved internally for the operang mode
"MS: Velocity mode".
Diagnoscs and fault eliminaon
Diagnoscs parameter
Wireless-LAN diagnoscs
84

Table of Contents

Other manuals for Lenze I51AE175B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze I51AE175B and is the answer not in the manual?

Lenze I51AE175B Specifications

General IconGeneral
BrandLenze
ModelI51AE175B
CategoryInverter
LanguageEnglish

Related product manuals