11.3.2 WLAN basic sengs
The WLAN funconality can be congured via the following parameters.
Precondions
WLAN module has been plugged onto the interface X16 on the front of the inverter.
Details
The WLAN module can be connected and removed during operaon.
The WLAN module can either create an own WLAN network (access point mode, default
seng) or implement itself as a WLAN client in an already exisng WLAN network. For
details see the following subchapters.
The WLAN connecon is encrypted. The WLAN encrypon can be selected in 0x2441:009.
0x2441:012 can be used to set that the name of the WLAN network, called SSID, is not
visible for other WLAN devices. As a result, the number of WLAN networks displayed on
smartphone or PC can be reduced.
Two data sources are possible for the WLAN sengs: Inverter and WLAN module.
Data source - inverter: The WLAN sengs saved in the inverter are used. Each inverter
has its own WLAN sengs.
Data source - WLAN module: The WLAN sengs saved in the WLAN module are used.
In this "stand-alone" mode, the WLAN module can be plugged onto another inverter
and then be used with the same sengs (irrespecve of the WLAN sengs of the
inverter).
The data source is acvated with 0x2440.
The currently acve data source is displayed in 0x2442:004.
Parameter Name / value range / [default seng] Info
0x2440 Iniate WLAN
From version 02.00
Restart WLAN network with default seng or current sengs.
0 No acon/no error Only status display.
1 Restart with current values (from
version 04.00)
Restart WLAN network with current sengs of the WLAN parameters.
The WLAN sengs of the acve data source (inverter or WLAN mod-
ule) are used.
The acve data source is displayed in 0x2442:004.
The data source is not changed by this selecon.
Note!
This selecon is currently not supported by the WLAN module V1.0.
2 Restart with default values Restart WLAN network with default seng of the WLAN parameters.
The WLAN sengs saved in the WLAN module are deleted.
Acve data source for the WLAN sengs is now the inverter.
11 Save sengs in WLAN module Restart WLAN network with current sengs of the WLAN parameters.
The current sengs are saved in the WLAN module.
Acve data source for the WLAN sengs is now the WLAN module.
0x2441:004 WLAN sengs: DHCP
From version 02.00
1 = Dynamic Host Conguraon Protocol (DHCP) is enabled.
In the access point mode, the DHCP server of the WLAN module is
acvated.
In the client mode, the DHCP-client funcon is acvated.
0 Disabled
1 Enabled
0x2441:005 WLAN sengs: DHCP start address
0 ... [0] ... 4294967295
From version 02.00
Denion of the start address when the Dynamic Host Conguraon
Protocol (DHCP) is used.
Only relevant for access point mode.
When 0 is set, the acve IP address + 1 is used as start address.
0x2441:006 WLAN sengs: WLAN operaon mode
From version 02.00
Denion of the operang mode of the WLAN module.
0 Access point mode For a direct connecon to another WLAN device, the WLAN module cre-
ates an own WLAN network.
4WLAN access point mode ^ 261
1 Client mode The WLAN module can be integrated as WLAN client into an already
exisng WLAN network.
4WLAN client mode ^ 266
Addional funcons
Wireless LAN (WLAN)
WLAN basic sengs
258

Table of Contents

Other manuals for Lenze I51AE175B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze I51AE175B and is the answer not in the manual?

Lenze I51AE175B Specifications

General IconGeneral
BrandLenze
ModelI51AE175B
CategoryInverter
LanguageEnglish

Related product manuals