11.2.5 Keypad - Conguraon of R/F and CTRL buons
Keypad rotaon setup
Use the
R
F
keypad to reverse the rotaon direcon at local keypad control.
Aer the
R
F
key has been pressed, the reversal of rotaon direcon must be conrmed
with the key. (The key serves to cancel the acon.)
MAN AUTO SETLOC REM
Keypad direction?
0 0 0 O r E V
MAN AUTO SETLOC REM
Hz
0 0 0 O 2 O O
VEL:RUN:FWD
R
F
MAN AUTO SETLOC REM
Hz
0 0 0 - 2 O O
VEL:RUN:REV
The keypad key
R
F
directly changes the keypad rotaon setup in 0x2602:002 (P708.02).
has no funcon in case of a bipolar setpoint selecon (e. g. ±10 V). In this case, the direc-
on of rotaon is determined by the sign of the setpoint.
has no funcon if the rotaon limitaon "Only clockwise (CW) [0]" is set in 0x283A
(P304.00).
has no funcon in the operang mode 0x6060 (P301.00) = "MS: Torque mode [-1]".
has no funcon if the PID control is acvated.
can be deacvated in 0x2602:001 (P708.01).
Addional funcons
Keypad
Keypad - Conguraon of R/F and CTRL buons
254

Table of Contents

Other manuals for Lenze I51AE175B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze I51AE175B and is the answer not in the manual?

Lenze I51AE175B Specifications

General IconGeneral
BrandLenze
ModelI51AE175B
CategoryInverter
LanguageEnglish

Related product manuals