5.3.3 Basic motor sengs
Check the following default sengs for the motor and motor control and adapt them, if
required.
Drive behaviour by default
By default, the V/f characterisc control with a linear characterisc is preset as motor control
for asynchronous motors. The V/f characterisc control is a motor control for convenonal
frequency inverter applicaons. It is based on a simple and robust control mode for the opera-
on of asynchronous motors with a linear or square-law load torque characterisc (e.g. fan).
Because of the minimal parameterisaon eort, such applicaons can be commissioned easily
and quickly.
The default sengs of the parameters ensure that the inverter is ready for operaon imme-
diately and the motor works adequately without further parameterisaon if an inverter and
an asynchronous motor* Hz asynchronous machine with matching performances are
assigned to each other.
* Depending on the device/mains frequency either 50-Hz asynchronous motor or 60-Hz asyn-
chronous motor.
Parameter Name / value range / [default seng] Info
0x2B01:001
(P303.01)
V/f shape data: Base voltage
(V/f shape data: Base voltage)
0 ... [230]* ... 5000 V
* Default seng depending on the size.
Base voltage and base frequency dene the V/f rao and thus the gradi-
ent of the V/f characterisc.
The V/f base voltage is usually set to the rated motor voltage
0x2C01:007 (P320.07).
The V/f base frequency is usually set to the rated motor frequency
0x2C01:005 (P320.05).
0x2B01:002
(P303.02)
V/f shape data: Base frequency
(V/f shape data: Base frequency)
Device for 50-Hz mains: 0 ... [50]* ... 1500 Hz
Device for 60-Hz mains: 0 ... [60]* ... 1500 Hz
* Default seng depending on the size.
0x2C00
(P300.00)
Motor control mode
(Motor ctrl mode)
Seng can only be changed if the inverter is inhibi-
ted.
Selecon of the motor control type.
3 Sensorless control (SL PSM) (from
version 02.00)
This control type is used for the sensorless control of a synchronous
motor.
4Sensorless control for synchronous motors (SL-PSM) ^ 125
4 Sensorless vector control (SLVC) This control type is used for sensorless vector control of an asynchro-
nous motor.
4Sensorless vector control (SLVC) ^ 122
6 V/f characterisc control (VFC open loop) This control mode is used for the speed control of an asynchronous
motor via a V/f characterisc and is the simplest control mode.
4V/f characterisc control (VFC) ^ 116
0x2C01:010 Motor parameters: Motor name The name (e.g. " 1") can be freely selected by the user.
If the motor in the engineering tool has been selected from the "motor
catalog", the respecve motor name is automacally entered here
(example: "MDSKA080-22, 70").
0x6075
(P323.00)
Motor rated current
(Motor current)
0.001 ... [1.700]* ... 500.000 A
* Default seng depending on the size.
Seng can only be changed if the inverter is inhibi-
ted.
The rated motor current to be set here serves as a reference value for
dierent parameters with a seng/display of a current value in percent.
Example:
Motor rated current = 1.7 A
Max current 0x6073 (P324.00) = 200 % Motor rated current = 3.4 A
All possible sengs with regard to the motor and motor control are described in the "Motor
control" chapter. ^ 113
Commissioning
Parameter seng
Basic motor sengs
44

Table of Contents

Other manuals for Lenze I51AE175B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze I51AE175B and is the answer not in the manual?

Lenze I51AE175B Specifications

General IconGeneral
BrandLenze
ModelI51AE175B
CategoryInverter
LanguageEnglish

Related product manuals