Parameter Name / value range / [default seng] Info
0x6073
(P324.00)
Max current
(Max current)
0.0 ... [200.0] ... 3000.0 %
Maximum overload current of the inverter.
•
100 % ≡ Motor rated current 0x6075 (P323.00)
•
If the current consumpon of the motor exceeds this current limit,
the inverter changes its dynamic behaviour, in order to counteract this
exceedance.
•
If the change in the dynamic behaviour carried out by the inverter
does not result in exing the overcurrent state, the inverter outputs
an error.
Note!
This parameter is not idencal to the so-called ulmate motor current
I
ULT
!
•
The ulmate motor current set in 0x2D46:001 (P353.01) is a limit
value for synchronous motors that serves to protect their magnets.
•
The value to be set here should always be considerably below the ul-
mate motor current!
0x2D88
(P104.00)
Motor current
(Motor current)
•
Read only: x.x A
Display des present current-r.m.s. value.
0x6078
(P103.00)
Current actual value
(Current actual)
•
Read only: x.x %
Display of the present motor current.
•
100 % ≡ Motor rated current 0x6075 (P323.00)
Motor control
Motor protecon
Current limits