6 Diagnoscs and fault eliminaon
6.1 LED status display
The "RDY" and "ERR" LED status displays on the front of the inverter provide some quick infor-
maon about certain operang states.
"RDY" LED (blue) "ERR" LED (red) Status/meaning
o o No supply voltage.
on on
Inialisaon (inverter is started.)
blinking (1 Hz)
o
Safe torque o (STO) acve.
blinking fast (4 Hz)
Safe torque o (STO) acve, warning acve.
blinking (2 Hz)
o Inverter inhibited.
blinking fast (4 Hz)
Inverter disabled, warning acve.
4Error handling ^ 90
on
Inverter disabled, error acve.
4Error handling ^ 90
lit every 1.5 s for a
short me
Inverter inhibited, no DC-bus voltage.
on for a short me
every 1 s
USB module is connected, 5-V supply voltage for the USB module is available.
on
o
Inverter enabled.
The motor rotates according to the specied setpoint or quick stop acve.
blinking fast (4 Hz)
Inverter enabled, warning acve.
The motor rotates according to the specied setpoint or quick stop acve.
blinking (1 Hz)
Inverter enabled, quick stop as response to fault acve.
4Error handling ^ 90
Both LEDs are blinking in a rapidly alternang
mode
Firmware update acve.
4Firmware download ^ 322
Both LEDs are blinking in a very rapidly synchro-
nous mode
"Visual tracking" funcon is acve.
4Opcal device idencaon ^ 112
Diagnoscs and fault eliminaon
LED status display
67