Troubleshooting Flow Chart for 40 W Transmitter Section 12: 3-3
6881091C63-F
2.0 Troubleshooting Flow Chart for 40 W Transmitter (Sheet 1 of 2)
Control
Voltage at
TP4533
>1V
Current
increase
when
keyed?
NO
YES
START
Check if Pressure Pad closes S5440
Check Components between
Q4441 and RF Output,
Antenna Switch
D4471,D4472,Q4472,
VR4471,Q4471
>500mA & <6A
>6A
<500mA
Check PA Stages
Short TP4531 to
Ground
NO
NO
Voltage at
TP4533
rises?
Check PA Stages
YES
YES
PCIC U4501
Pin 14 9.3V
DC?
Check 9.3 V Regulator
U0641
NO
YES
PCIC U4501
Pin 16 >4V
DC
Replace PCIC U4501
NO
YES
TP4530
9.1V DC
If U4201 Pin 2 is high,
replace PCIC
U4501,otherwise
check controller and
FGU
YES
NO
TP4531
>0.5V DC?
Replace PCIC U4501
Check Forward Power
Sense Circuit (D4451)
Check Forward Power
Sense Circuit (D4451)
NO
YES
PCIC U4501
Pin 5 > 1V
DC?
Check Power Setting,
Tuning & Components
between PCIC Pin 5
and ASFIC (U0221)
Pin 4 before replacing
ASFIC
No power or low power when keyed
Put in pressure pad
YES
NO
1
Is Q4473
OK?
Change
Q4473
NO
YES
Check voltage
on pin 4
U4501
NO
YES
Check
R4422-5 and
go back to top
1

Table of Contents

Other manuals for Motorola CDM1250

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motorola CDM1250 and is the answer not in the manual?

Motorola CDM1250 Specifications

General IconGeneral
DisplayAlphanumeric
IP RatingIP54
Frequency RangeVHF: 136-174 MHz, UHF: 403-470 MHz
SignalingPL, DPL, MDC1200, Quick Call II
Operating Temperature-22°F to +140°F (-30°C to +60°C)
Power OutputVHF: 1-25W; UHF: 1-25W

Related product manuals