Engine System - LPG 160Service Manual – CS7000
Engine Starter Control
To get the engine starter to engage, the key switch is held in the start position which supplies
36 volts to the main machine controller on the violet wire with the green stripe to connector J7
pin 19. This is the start input request. The main machine controller receives a 12 V supply on
connector J3 pin 23 from the engine starter battery. It uses this voltage supply to send 12 volts out
of connector J3 pin 10 to the crank request relay coil. The other side of the relay coil is grounded
through the Woodward L-series actuator. With power and ground across the relay winding
the relay energizes and fused battery power from terminal 30 is sent to the starter solenoid.
15A
12v BATTERY
STARTER
CRANK
REQUEST
RELAY
Main Machine Controller
Ground
Battery
Cranking
12v
WOODWARD
L-SERIES
ACTUATOR
36v BATTERY
36v
Aux. Relay Contact
12v
Key Switch
Start Position

Table of Contents

Other manuals for Nilfisk-Advance CS7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-Advance CS7000 and is the answer not in the manual?

Nilfisk-Advance CS7000 Specifications

General IconGeneral
BrandNilfisk-Advance
ModelCS7000
CategoryFloor Machine
LanguageEnglish

Related product manuals