Dust Control/DustGuard
Systems 86Service Manual – CS7000
Circuit Description
The following conditions must be met for the DustGuard™ system to operate:
The DustGuard™ system must be installed in the conguration menu.
There must be positive voltage to the J7-1 Interlock Input. For this to happen:
The Seat Switch S9 must be closed.
The Safety Relay K14 on the Steer By Wire Controller A5 must energize the coil to close the Safety Relay
K14
contactor.
The Emergency Stop Switch S15 must be closed.
The Battery Interlock S13 must be closed (battery machines) or jumpered (Diesel and LPG machines).
The 400-amp Fuse F1 must be closed to provide positive voltage from the Battery to the load side of Auxiliary
Contactor K9
, and to the 10-amp circuit breaker CB5.
The Ignition Switch S14 must be closed to provide positive voltage to the Auxiliary Contactor K9 coil. The
J2-14 Output on the A1 Main Machine Controller provides ground to the Auxiliary Contactor K9 coil when the
Ignition Switch S14 provides an input to the Key Switch Input J7-12.
The Auxiliary Contactor K9 must be closed to provide positive voltage to circuit breaker VACC2/CB2.
Circuit breaker VACC1/CB1 must closed to provide positive voltage to the Dust Control Motor Contactor K6
coil and the Shaker Motor M14.
The J2-6 Output provides the negative ground to the Dust Control Motor Contactor K6 coil under the
following conditions:
If the hopper is down:
The A1 Main Machine Controller must receive a signal from the A3 Control Panel via the CAN BUS that
the operator has pressed the DustGuard™ spray switch (blue LED on).
The A1 Main Machine Controller must receive a signal from the A2 Drive Controller via the CAN BUS
that the machine is moving forward or backward.
If the hopper is up, the A1 Main Machine Controller must receive a signal from the A3 Control Panel via
the CAN BUS that the operator has pressed the DustGuard™ spray switch. Note that the seat switch
does not have to be closed.
Circuit breaker CB5 must closed to provide positive voltage to the load side of Dust Control Motor Contactor
K6
.
Dust Control Motor Contactor K6 must be closed to provide positive voltage to the Dust Control Motor M5.
Dust Control Motor M5 must be connected to battery ground.
Circuit breaker VACC2/CB2 must closed to provide positive voltage to the DustGuard Valve L2 and the
DustGuard Pump M22.
The J3-13 Output provides the negative ground to the DustGuard Valve L2 and the DustGuard Pump M22
under the following conditions:
The A1 Main Machine Controller must receive a signal from the A3 Control Panel via the CAN BUS that the
operator has pressed the DustGuard™ spray switch (blue LED on).

Table of Contents

Other manuals for Nilfisk-Advance CS7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-Advance CS7000 and is the answer not in the manual?

Nilfisk-Advance CS7000 Specifications

General IconGeneral
BrandNilfisk-Advance
ModelCS7000
CategoryFloor Machine
LanguageEnglish

Related product manuals