Dust Control/DustGuard
™
Systems 99Service Manual – CS7000
To Disassemble and Reassemble the Impeller Assembly
1. Remove the three Nyloc™ Nuts, Screws
and Spacers holding the Vacuum Plate
and Gasket
to the Vacuum Support and
attached Vacuum Motor.
2. Remove the three Nyloc™ Nuts holding
the Vacuum Motor to the Vacuum
Support
and remove the Vacuum Motor.
Note: To prevent the three
Screws from spinning
when removing the
Nyloc™ Nuts to remove
the Vacuum Motor, place
a wrench on the Screw
heads under the Vacuum
Motor Tabs
.
3. Reassemble the impeller assembly
following the above steps in reverse
order.
Vacuum
Plate and
Gasket
Vacuum
Support
Screw (3)
Nyloc™
Nut (3)
Spacer (3)
Vacuum
Motor
Screw (3)
Nyloc™
Nut (3)
Vacuum
Support
Vacuum
Motor
Gasket
Vacuum
Plate
Protection
Grate
Vacuum
Support
Nyloc™ Nut
(typical)
Screw
(typical)
Vacuum
Motor
Tab