Solution System 335Service Manual – CS7000
Removal and Installation
Warning! Before removing or reinstalling any machine components, make sure the key switch
is off, the key is removed from the machine and the parking brake is engaged.
To Remove and Reinstall the Solution Tank
Caution: The solution tank is relatively heavy. It’s recommended that the solution tank be
removed by two or more persons, using the appropriate equipment, to prevent
possible personal injury or damage to the solution tank.
1. Disconnect the battery/batteries.
2. Drain and remove the recovery tank.
3. Drain the solution tank.
4. Disconnect the solution hoses from the solution tank.
5. Disconnect the electrical connector from the Drive
Pedal
.
6. Remove the Brake Pedal Cover Weldment.
7. Remove the Circuit Breaker Panel and disconnect the
circuit breaker connectors.
Note: Label the circuit breaker connectors as
you remove them to make sure they are
reconnected correctly.
Brake Pedal
Cover Weldment
Drive
Pedal
Circuit Breaker
Panel