Sweep System, Main 393Service Manual – CS7000
Specications
Component Specications
Main Broom Motor
RPM - 3400
Voltage - 36 VDC
Amperage - 26 Amps
Main Broom Actuator
Dynamic Load - 400 lbs. maximum
Static Load - 1000 lbs. maximum
Restraining Torque - Actuator is internally restrained
Input Voltage - 30 to 40 VDC
Amperage - 4 Amps at rated dynamic load
Overload Protection - Ball detent clutch with load rating between 450 and 700 lbs.
Thermal Protection - Automatic resetting thermal breaker enclosed in motor housing.
Wiring Polarity:
• To extend actuator, connect red lead to positive and yellow lead to negative.
• To retract actuator, connect yellow lead to positive and red lead to negative.