Use this SP to set the threshold value of the firmware counter to trigger the full alert
for the right ink sump.
Reset and Restoration Settings
3-008-001
RST:INIT CNT:F Reset Initial Tank Fill Count to Manufacturing
Operation Count
Resets the initial fill counter to the initial factory setting (-2).
3-008-002 RST:INIT CNT:A Reset Initial Tank Fill Count to Factory Shipping
Resets the initial fill counter to the initial factory setting before shipping (-1).
3-008-003
RST:WASTE:RC Reset Ink Collector Count/Flag: Right Ink
Collector unit
Resets the ink flag and ink counter for the right Ink Collector unit.
3-008-004 RST:WASTE:R Reset Ink Collector Count/Flag: Right Ink Sump
Resets the ink counter for the right ink sump.
3-008-005 RST:FACT Restore Factory Default Setting
Resets and threshold settings and user adjusted values.
Maintenance, Replacement
3-009-001 WASHING Execute Auto Washing
Executes the automatic flushing procedure.
3-009-002 CARRIAGE CHANGE After Carriage Replacement
Execute this SP after replacing the carriage unit.
SP4-XXX
Not used.
SP Mode Service Tables