RIGOL 7 Protocol Decoding
7-14 DS6000 User’s Guide
adjustable range of the timeout time is from 100 ns to 1 s. The default is 1
μs.
When "CS" is selected, press SS to enter the SS (chip select line) setting
interface.
Press Channel and select any channel of CH1 to CH4 as the CS
channel.
Press Polarity to set the polarity of the chip select channel to high
(
) or low ( ).
Press Threshold to set the threshold of the chip select channel.
2. SCLK Setting
Press SCLK to turn on the clock line setting interface.
Press Channel to select any channel (CH1-CH4) as the clock channel.
Press Slope to set the oscilloscope to sample MISO and MOSI on the rising
edge (
) or falling edge ( ) of SCLK.
Press Threshold to set the threshold of the clock channel.
3. MISO Setting
Press MISO to turn on the MISO data line setting interface.
Press Channel to select any channel (CH1 to CH4) as the MISO channel.
When "None" is selected, this data line will not be set. Note: When the
MOSI data line is set to "None", the MISO data channel cannot be set to
"None".
Press Polarity to set the polarity of the MISO data line to high ( ) or
low (
).
Press Threshold to set the threshold of the MISO data line.
4. MOSI Setting
Press MOSI to turn on the MOSI data line setting interface.
Press Channel to select any channel (CH1-CH4) as the MOSI channel.
When "None" is selected, this data line will not be set. Note: When the
MISO data line is set to "None", the MOSI data channel cannot be set to
"None".
Press Polarity to set the polarity of the MOSI data line to high ( ) or
low (
).
Press Threshold to set the threshold of the MOSI data line.

Table of Contents

Other manuals for Rigol DS6104

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS6104 and is the answer not in the manual?

Rigol DS6104 Specifications

General IconGeneral
BrandRigol
ModelDS6104
CategoryTest Equipment
LanguageEnglish

Related product manuals