10 Waveform Recording RIGOL
DS6000 User’s Guide 10-7
Waveform Analysis
This function is used to analyze the recorded waveform. Press UTIL Record
Mode and use to select "Analyze" to open the waveform analysis menu. At this
point, the screen is divided into two display areas as shown in the figure below.
Please set the related parameters of waveform analysis by referring to the following
explanations.
1. Analysis
Press Analyze to select the desired analysis mode.
Trace: Perform analysis on the basis of the template selected by users. For
detailed introduction, refer to "Analysis Based on Trace".
Pass/Fail: perform analysis on the basis of the Pass/Fail mask created by
users. For detailed introduction, refer to "Analysis Based on Pass/Fail
Mask".
2. Source
Press Source to select the channel (CH1-CH4) to be analyzed. Note that only
channels currently enabled can be selected.
Settings and Results Template Display Current Frame