12 Store and Recall RIGOL
DS6000 User’s Guide 12-3
Storage Type
Press SAVE Storage to select the desired storage type. The descriptions of the
save and load methods for each storage type are as follows. If a USB storage device
does not connect to the instrument, "Picture" and "CSV" under the Storage menu
are disabled.
1. Traces
Save the waveform data in internal or external memory in "*.trc" format. At
most 10 trace files (from LocalTrace0.trc to LocalTrace9.trc) can be stored in the
internal memory. The data of all the channels turned on can be saved in the
same file. At recall, the data will be displayed on the screen directly.
Note:
You can only save and load the files in "*.trc" format through the operation
buttons on the front panel of the digital oscilloscope.
After loading the files in "*.trc" format, press Clear to clear the loaded
waveforms; and meanwhile, the waveforms displayed on the screen will all
be cleared. (If the oscilloscope is in the "RUN" state, it will continue to
display the new waveforms.)
2. Waveforms
Save the waveform data in internal or external memory in "*.wfm" format. At
most 10 waveform files (from LocalWfm0.wfm to LocalWfm9.wfm) can be
stored in internal memory. The stored files contain the waveform data of the
four analog channels and the main setting information of the oscilloscope and all
the data can be recalled.
Note:
You can only save and load the files in "*.wfm" format through the
operation buttons on the front panel of the digital oscilloscope.
After loading the files in "*.wfm" format, the oscilloscope is in the "Stop"
state. Change the state of the oscilloscope into "RUN", and the oscilloscope
will restart the waveform sampling. (The loaded waveform data will be
cleared.)
3. Setups
Save the settings of the oscilloscope in internal or external memory in "*.stp"

Table of Contents

Other manuals for Rigol DS6104

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS6104 and is the answer not in the manual?

Rigol DS6104 Specifications

General IconGeneral
BrandRigol
ModelDS6104
CategoryTest Equipment
LanguageEnglish

Related product manuals