Home
Rigol
Test Equipment
DS6104
Rigol DS6104 User Manual
4
of 1
of 1 rating
298 pages
Give review
Manual
Specs
To Next Page
To Next Page
To Previous Page
To Previous Page
Loading...
4
To Set
the S
ample
Syst
em
RI
GOL
DS6000
User’s Gui
de
4-3
nu
mbe
r o
f
averag
es
. The number
of ave
ra
ges can
be set to 2,
4, 8,
16, 32, 64
, 128,
256, 51
2, 1024
, 204
8, 4096
or 819
2 and t
he def
ault is 2
.
The W
avefo
rm before Av
erage:
The W
avef
orm after 256 A
verages:
94
96
Table of Contents
Guaranty and Declaration
3
Safety Requirement
4
General Safety Summary
4
Safety Notices and Symbols
7
Allgemeine Sicherheits Informationen
8
Sicherheits Begriffe und Symbole
11
Measurement Category
12
Ventilation Requirement
13
Working Environment
14
Pollution Degree
15
Pollution Degree Definitions
15
Care and Cleaning
16
Environmental Considerations
17
DS6000 Series Overview
19
Document Overview
21
Table of Contents
24
1 Quick Start
31
General Inspection
32
Appearance and Dimensions
33
Preparations for Use
34
To Remove the Cover
34
To Adjust the Supporting Legs
35
To Connect to AC Power Supply
36
To Use the Battery
37
Power-On Inspection
38
To Connect the Probe
39
Function Inspection
42
Probe Compensation
44
Front Panel Overview
45
Rear Panel Overview
47
Front Panel Function Overview
49
Vertical
49
Horizontal
51
Trigger
52
Run/Stop
52
Single
53
Auto
53
Multifunction Knob
54
Navigation Knob
54
Function Keys
55
Record
55
Meas
56
Clear
56
Print
56
User Interface
57
Trigger Type
59
Security Lock
63
Desk Mount Instrument Arm
64
Built-In Help System
65
2 To Set the Vertical System
67
To Enable the Channel
68
Channel Coupling
69
Bandwidth Limit
70
Probe
71
Input Impedance
75
Waveform Invert
75
Vertical Scale
76
Vertical Position
77
Vertical Expansion
78
Amplitude Unit
78
Channel Label
79
Delay Calibration
80
3 To Set the Horizontal System
81
Delayed Sweep
82
Time Base Mode
84
Y-T Mode
84
X-Y Mode
85
Roll Mode
88
Horizontal Scale
89
Horizontal Position
89
Horizontal Reference
91
4 To Set the Sample System
93
Acquisition Mode
94
Normal
94
Average
94
Peak Detect
96
High Resolution
96
Sample Mode
97
Real-Time Sample
97
Equivalent Sample
97
Sample Rate
98
Memory Depth
100
Anti-Aliasing
101
5 To Trigger the Oscilloscope
103
Trigger Source
104
Trigger Mode
105
Trigger Coupling
107
Trigger Holdoff
108
Trigger Type
109
Edge Trigger
110
Pulse Trigger
112
Slope Trigger
114
Time Setting
115
Vertical Window
115
Video Trigger
117
Pattern Trigger
119
RS232 Trigger
121
I2C Trigger
123
SPI Trigger
126
CAN Trigger
128
Flexray Trigger
131
USB Trigger
133
Trigger Output Connector
135
6 To Make Measurements
137
Math Operation
138
Addition
138
Subtraction
139
Multiplication
139
Division
141
Fft
142
Logic Operation
145
Advanced Operation
147
Auto Measurement
150
Quick Measurement after Auto
151
One-Key Measurement
152
Frequency Counter Measurement
159
Measurement Setting
160
To Clear the Measurement
162
All Measurement
163
Statistic Function
164
Measurement History
164
Cursor Measurement
165
Manual Mode
167
Track Mode
171
Auto Mode
175
X-Y Mode
176
7 Protocol Decoding
179
Parallel Decoding
180
RS232 Decoding (Option)
183
I2C Decoding (Option)
188
SPI Decoding (Option)
191
CAN Decoding (Option)
195
Flexray Decoding (Option)
199
8 Reference Waveform
203
To Enable REF Function
204
To Set the Color
205
To Select REF Source
206
To Save to Internal Memory
206
To Adjust REF Waveform Display
206
To Export to Internal or External Memory
207
To Import from Internal or External Memory
207
9 Pass/Fail Test
209
To Enable Pass/Fail Test Function
210
To Select Source
211
Mask Range
211
Test and Output
212
To Save the Test Mask
213
To Load the Test Mask
213
10 Waveform Recording
215
Record Constant on
218
Waveform Playback
219
Waveform Analysis
221
Analysis Based on Trace
224
Analysis Based on Pass/Fail Mask
225
11 Display Control
227
To Select the Display Type
228
To Set the Persistence Time
229
To Set the Waveform Brightness
231
To Set the Screen Grid
231
To Set the Grid Brightness
231
To Set the Menu Display
231
12 Store and Recall
233
Storage System
234
Storage Type
235
Internal Store and Recall
237
External Store and Recall
240
Disk Management
242
To Select File Type
243
To Create a New File or Folder
244
To Delete a File or Folder
247
To Rename a File or Folder
247
To Clear the Local Memory
248
Factory
249
13 System Function Setting
257
Remote Interface Configuration
258
LAN Setting
258
USB Device
262
To Set the GPIB Address
262
System-Related
263
Sound
263
Language
263
System Information
263
Power-Off Recall
264
System Time
264
Self-Calibration Information
265
Screen
265
Error Information
266
Self-Calibration
266
Power Status
267
External Trigger Impedance
267
Aux Output
267
Reference Clock
268
Option Management
269
To Print the Waveform
271
To Connect the Print Device
271
Normal Print
272
Pictbridge Print
273
14 Remote Control
275
Remote Control Via USB
276
Remote Control Via LAN
280
Remote Control Via GPIB
282
15 Troubleshooting
285
16 Specifications
287
General Specifications
294
Calibration Interval
294
17 Appendix
295
Appendix A: Accessories and Options
295
Appendix B: Warranty
296
Index
297
Other manuals for Rigol DS6104
How-To Guide
8 pages
Performance Verification Guide
43 pages
Quick Guide
41 pages
Declassification Guide
16 pages
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Rigol DS6104 and is the answer not in the manual?
Ask a question
Rigol DS6104 Specifications
General
Brand
Rigol
Model
DS6104
Category
Test Equipment
Language
English
Related product manuals
Rigol DS6064
298 pages
Rigol DS6062-DEMO
298 pages
Rigol DS6000 Series
298 pages
Rigol DS1054
66 pages
Rigol DS7034
259 pages
Rigol DS1104Z
38 pages
Rigol DS1052E
166 pages
Rigol DS2302A
335 pages
Rigol DS1102E
166 pages
Rigol DS1054Z
268 pages
Rigol DS1102D
166 pages
Rigol DS1102/4B
164 pages