198 Rockwell Automation Publication 1766-UM001O-EN-P - September 2021
Appendix F MicroLogix 1400 Distributed Network Protocol
DNP3 Slave Application Layer Configuration Parameters
Channel for Unsolicited Response
Only channels already configured for DNP3 protocol appear in the Channel for
Unsolicited Response dropdown menu. Any and all Unsolicited Responses are
transmitted via this selected channel.
Channel 1 is only supported in MicroLogix 1400 Series B and Series C
controllers.
Valid selections are Enabled (Checked) and Disabled (Unchecked), with
disabled as default value.
Restore Events After Power Cycle
When the selection is Disabled (Unchecked), DNP3 events which are generated
before a power cycle are flushed after a power cycle. When the option is
Enabled (Checked), all DNP3 events are restored after a power cycle.
Enable Unsolicited On Start Up
Valid selections are Enabled (Checked) and Disabled (Unchecked). Default
value is Disabled (Unchecked).
When the selection is Disabled (Unchecked), the controller does not send any
enabled Unsolicited Responses after a restart until it has received a
FC_ENABLE_UNSOLICITED (20) command from the DNP3 Master.
When the selection is Enabled (Checked), the controller sends any enabled
Unsolicited Responses after a restart to the DNP3 Master unconditionally.
Enable Unsolicited For Class1
Valid selections are Enabled (Checked) and Disabled (Unchecked). Default
value is Disabled (Unchecked).
When the selection is Disabled (Unchecked), Unsolicited Response is disabled
for Class 1 events. To prevent overflowing of the event buffer, DNP3 Master
should poll for Class 1 events.
When the selection is Enabled (Checked), Unsolicited Response is enabled for
Class 1 events.
Enable Unsolicited For Class2
Valid selections are Enabled (Checked) and Disabled (Unchecked). Default
value is Disabled (Unchecked).
When the selection is Disabled (Unchecked), Unsolicited Response is disabled
for Class 2 events. To prevent overflowing of the event buffer, DNP3 Master
should poll for Class 2 events.
When the selection is Enabled (Checked), Unsolicited Response is enabled for
Class 2 events.
Enable Unsolicited For Class3
Valid selections are Enabled (Checked) and Disabled (Unchecked). Default
value is Disabled (Unchecked).

Table of Contents

Other manuals for Rockwell Automation 1766-L32BWAA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation 1766-L32BWAA and is the answer not in the manual?

Rockwell Automation 1766-L32BWAA Specifications

General IconGeneral
BrandRockwell Automation
Model1766-L32BWAA
CategoryController
LanguageEnglish

Related product manuals