Chapter 2 General notes for service technicians
14 SMSO-2-02.02- 15.07.03
2.2 Service instructions
2.2.1 Service intervals for the Ambiente-2 coffee machine (Index e, 30.06.2003)
Servicing must take place after every 45,000 coffee servings, or every 12 months
A = Parts relevant to safety (see this section)
No. 1-22 = check no. (see Section „Instructions on check numbers 1-22")
Description of part
Part
no.
After 45,000 coffee serv-
ings or after 12 months
After xx months or
max. counter reading
C R R
Instant heater – coffee to 12/2000
Instant heater – coffee from 01/2001
A
A
065‘111
1
36 months
60 months
(Section "Safety-relevant
parts, point 1")
Supply pipe 063‘404
2
HW valve pipe 063‘205
3
Safety valve
A
065‘240
R
3/2-way brewing valve
2/2-way brewing valve
063‘206
063‘215
R
R
Draining valve 061‘029
R
Instant heater brewing valve pipe 063‘405
3
Booster 061‘823
4
Instant heater – tea to 12/2000
Instant heater – tea from 01/2001
A
A
061‘164
1
36 months
60 months
(Section "Safety-relevant
parts, point 1")
Supply pipe 063‘204
2
Safety valve
A
065‘240
R
HW valve tea 063‘215
R
Steam generator to 12/2000
Steam generator from 01/2001
A
A
061‘156
1
36 months
60 months
(Section "Safety-relevant
parts, point 1")
Supply pipe 063‘304
2
Level probe 067‘068
5
Safety valve
A
065‘240
R
Safety valve pipe 065‘154
2
Steam valve 063‘715
R
Feed valve 063‘215
6 36 months
Grinder motor 062‘431
7 100‘000
Grinder blade 065‘007
8 80‘000
Brewing unit 065‘000
9 70‘000
Lower piston with O-ring system 065‘316
R
Outlet piston 065‘310
R
Friction ring for 065316 065‘191
R
Lower piston / outlet piston O-ring 065‘190
R
Piston motor 063‘322
10 100‘000
Flow meter 061‘226
11 36 months
Non-return valve 063‘208
12 36 months
Pump distribution block pipe 063‘455
13 36 months
Distribution block - instant heater pipe Tea 063‘518
13 36 months
Distribution block – steam generator pipe 063‘519
13 36 months
Distribution block – flow meter pipe 063‘452
13 36 months
Instant heater – tea outlet pipe 063‘455
13 36 months
Steam valve outlet pipe
Steam valve – outlet / refrigerator pipe
063‘523
063‘455
13
13
36 months
Flowmeter – instant heater- coffee 063‘450
13 36 months
Brewing valve - brewing unit pipe 063‘453
13 36 months
Brewing unit - outlet pipe 063‘513
13 36 months
Brewing valve - booster 061‘986
13 36 months
Booster – brewing unit 061‘987
13 36 months
Pump 065‘384
14
Motor 065‘003
15
C = check R = replace