Programming via SIMATIC controller
8.5 Programming Ident blocks
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
131
8.5.2.5
Set_Param
With the "Set_Param" block, you can change UHF parameters on an RF680R/RF685R
during runtime (e.g. the antenna power).
Note
Settings saved only temporarily
Note that the parameters in the "Set_Param" block are only stored temporarily. If the power
for the reader is interrupted, the stored values are lost and must be set again.
Figure 8-15 "Set_Param" block
Table 8- 15 Explanation of the "Set_Param" block
Parameter
Data type
Default values
Description
PARMID
DWORD
0x00
Parameter identifier
VALUE
DWORD
0x00
Parameter value