EasyManuals Logo
Home>Siemens>Other>SIMATIC RF650R

Siemens SIMATIC RF650R User Manual

Siemens SIMATIC RF650R
344 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #204 background imageLoading...
Page #204 background image
Programming via XML interface
10.3 XML commands
SIMATIC RF650R/RF680R/RF685R
204 Configuration Manual, 03/2018, C79000-G8976-C386-06
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 263)".
Parameter
Parameter
Type
Values
Description
value_id Decimal value
0...9
0...4294967295 Unique command identifier
value_logType Fixed values Diagnosis Optional
Type of diagnostics file
• Diagnostics: Log file
value_logData CDATA -- Data logged by the reader
The parameter must be embedded in a
CDATA segment.
10.3.2.6
resetLogfile
This command deletes all the entries in the log.
Command
<frame>
<cmd>
<id> value_id </id>
<resetLogfile/>
</cmd>
</frame>
Reply
<frame>
<reply>
<id> value_id </id>
<resultCode> 0 </resultCode>
<resetLogfile/>
</reply>
</frame>
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 263)".

Table of Contents

Other manuals for Siemens SIMATIC RF650R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC RF650R and is the answer not in the manual?

Siemens SIMATIC RF650R Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC RF650R
CategoryOther
LanguageEnglish

Related product manuals