EasyManuals Logo
Home>Siemens>Other>SIMATIC RF650R

Siemens SIMATIC RF650R User Manual

Siemens SIMATIC RF650R
344 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #201 background imageLoading...
Page #201 background image
Programming via XML interface
10.3 XML commands
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
201
Parameter
Parameter
Type
Values
Description
value_id Decimal value
0...9
0...4294967295 Unique command identifier
value_configData CDATA -- Configuration data
The parameter must be embedded in a
CDATA segment.
value_configID Alphanumeric text -- Unique identifier of the transferred
configuration
The ID can also be read out with the
"getConfigVersion" command.
10.3.2.3
getConfigVersion
This command requests the version of the configuration stored on the reader.
Command
<frame>
<cmd>
<id> value_id </id>
<getConfigVersion/>
</cmd>
</frame>
Reply
<frame>
<reply>
<id> value_id </id>
<resultCode> 0 </resultCode>
<getConfigVersion>
<returnValue>
<configID> value_configID </configID>
</returnValue>
</getConfigVersion>
</reply>
</frame>
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 263)".

Table of Contents

Other manuals for Siemens SIMATIC RF650R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC RF650R and is the answer not in the manual?

Siemens SIMATIC RF650R Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC RF650R
CategoryOther
LanguageEnglish

Related product manuals