Programming via XML interface
10.3 XML commands
SIMATIC RF650R/RF680R/RF685R
220 Configuration Manual, 03/2018, C79000-G8976-C386-06
The command returns all antennas that are configured at the specified read point.
This command is supported as of API protocol version V2.1.
<sourceName> value_ sourceName <sourceName>
<resultCode> 0 </resultCode>
<antennaName> value_antennaName </antennaName>
<antennaName> value_antennaName </antennaName> // opt
// opt → Optional: Line can be omitted.
The error codes for negative replies ("resultCode" ≠0) are described in the section "Negative
XML replies (Page 263)".