Programming via XML interface
10.3 XML commands
SIMATIC RF650R/RF680R/RF685R
254 Configuration Manual, 03/2018, C79000-G8976-C386-06
value_
commandRetry
Decimal value
0...9
0...65535 Optional
Number of times the reader repeated
commands attempting to obtain correct
data.
"0" corresponds to no attempt.
The maximum number of attempts is
value_airRetry Decimal value
0...9
0...65535 Optional
Number of times the reader repeated
air interface commands attempting to
obtain correct data.
"0" corresponds to no attempt.
The maximum number of attempts is
specified in the reader firmware and
value_
filterDataAvailable
Fixed values True
False
Optional
Indicates whether or not a filter criteri-
on was received.
• True:
No problem All the data was read
or there was no filter set.
• False:
With this command, the selected transponder is deactivated. If no EPC-ID is made available
or detected, the command is executed with all the transponders recognized from the read
point.
-ID is specified, the results are influenced by all the set filter mechanisms (refer to
The "Settings - Filters" menu item (Page 68)"). Then in the reply frame, only the
transponders that were not filtered out appear. If an EPC
-ID is specified, the data filter has
The reply frame contains the IDs of all identified transponders. A flag for each transponder
indicates whether or not the command was successful for this transponder.
If no transponder was identified, a negative reply is returned.