Appendix
A.3 Command and acknowledgement frames
SIMATIC RF650R/RF680R/RF685R
332 Configuration Manual, 03/2018, C79000-G8976-C386-06
Writes a new EPC-ID to the transponder.
Table A- 14 Command
0, 1 2, 3 4 5 6, 7 8 9 10 11 12
DBL SN CC CI TDB DBN_H DBN_L DBL -- SOURC
-- -- 'g' 'U' 1 -- 1 -- 0 0
-- -- NEW-
IDLENG
PSWD -- -- IDLENG
TH
EPC-ID NEW-
EPC-ID
Table A- 15 Reply
DBL SN CC STATUS TDB DBN_H DBN_L DBL
Table A- 16 Description of the bytes
Length of the new EPC-ID (2 ... 62 bytes)
18, 19 Password for transponder access:
• 0x00 = no password
26 Length of the EPC ID:
• 0x00 = not addressed
Buffer for up to 62 bytes EPC-ID
Length of the new EPC ID The length is specified in byte 16, 17.