Inventory
The "Inventory" block activates the taking of inventories. There are four different modes that
you can select with the "ATTRIBUTE" parameter.
At the start, a certain duration/number (period of time, number of inventories, number of
"observed" events or identified transponders) is specified. A distinction is made between
the following options:
Duration
Take inventories for a specified period of time
Number of inventories
Take a specified number of inventories
Number of "observed" events
Take inventories until a specified number of transponders have been identified at the
same time.
Inventories are then taken by the reader for this time or number of inventories. When the
specified time/number is reached, the block is ended and returns all identified
transponders in "IDENT_DATA". The transponders are sorted according to the RSSI
value (highest value first). In other words, other commands can only be executed when
all inventories have been taken completely. The unit (time or number) is specified using
"DUR_UNIT" and the value (time value or number) using "DURATION". This mode can
be executed using the attributes "0x80" and "0x81". Depending on the attribute, more or
less data is supplied about the identified transponders.
To be reported, a transponder must have had the "Observed" status at least once at the
start of or during the command execution time. The transponder is reported even if it
returned temporarily to the "Lost" status.
With the attributes "0x86" (start "Presence_Mode") and "0x87" (end "Presence_Mode"),
inventories can be taken permanently. The presence of a transponder can then always
be queried using "PRESENCE" without needing to start the block with "EXECUTE". No
information about the identified transponders is returned when the command executes!
To obtain information about the identified transponders, use one of the two calls listed
above (with time / number of inventories = 0).
When this mode is active, commands relating to transponders are not executed
immediately but only when a transponder is identified. This achieves shorter reaction
times since the command is already pending when the transponder enters the antenna
field.
The "Presence_Mode" is practical in the context of the "Repeat command" function.
The "NUMBER_TAGS" output parameter is used to output the number of identified
transponders. With the attributes "0x80" and "0x81" on completion of the read operation, the
sum of all identified transponders is displayed. With the attribute "0x86" the number of
currently identified transponders is shown at the "NUMBER_TAGS" output parameter (max.
15), without needing to start the module with "EXECUTE".

Table of Contents

Other manuals for Siemens SIMATIC RF650R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC RF650R and is the answer not in the manual?

Siemens SIMATIC RF650R Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC RF650R
CategoryOther
LanguageEnglish

Related product manuals