Service and maintenance
12.2 Error messages
SIMATIC RF650R/RF680R/RF685R
296 Configuration Manual, 03/2018, C79000-G8976-C386-06
Command repetition is not supported.
-- 0x7A 0xE7FE0A Error during the transfer of the PDU (Protocol Data Unit).
"--" means that the error is not displayed by the LEDs.
The following table lists the OPC UA-specific error codes.
Table 12- 3 OPC UA error messages of the RF600 readers
0x13 good 7 OUT_OF_RANGE_
ERROR
Address error
The address area of the transponder has been exceeded.
Possible causes:
• Start address of the command start has been incor-
rectly set.
• Wrong transponder type
• The area to be written to is write-protected.
0x1A good 3 PERMISSON_
The transponder is read/write-protected.
0x91 good 19 RF_COMMUNICATION_
The transponder is not responding.
0x92 good 4 PASSWORD_
The transponder password is incorrect. Access is denied.
0x93 good 19 RF_COMMUNICATION_
The verification of the written transponder data has failed.
0x94 good 19 RF_COMMUNICATION_
General transponder error
0x95 good 19 RF_COMMUNICATION_
The transponder has too little power to execute the com-
0x22 good 9 MULTIPLE_
IDENTIFIERS
More transponders are located in the transmission win-
dow than can be processed at the same time by the
0xA1 good 8 NO_
IDENTIFIER
There is no transponder with the required EPC-ID in the
transmission window or there is no transponder at all in
0xA2 good 7 OUT_OF_
The requested data is not available.
0xA3 good 19 RF_COMMUNICATION_
The transponder signals a CRC error.
The selected antenna is not enabled.