Configuring with the WBM
7.3 The menu items of the WBM
SIMATIC RF650R/RF680R/RF685R
54 Configuration Manual, 03/2018, C79000-G8976-C386-06
Intermissions
Random intermissions can be used to reduce the mutual influence between RFID devices in
environments with a high reader density.
The incidence and duration of the intermissions can be set depending on the required
availability of the RFID data. The following figure shows the effects of the intermissions:
Figure 7-5 Example of intermissions
Note
Delay due to intermissions
Remember that intermissions delay the other algorithms.
7.3.3
The "Settings - Read points" menu item
In the "Settings - Read points" menu, up to four logical read points can be defined depending
on the reader type. A logical read point is, for example, an incoming goods gate in logistics
or a machine infeed on a production line. A read point, on the other hand, can be assigned
one or more antennas required to cover the identification area of the read point.
The settings are structured identically for each read point and divided into the following 6
areas:
Read point name
Assigned antennas
Algorithms
Tag fields
Filters
Trigger

Table of Contents

Other manuals for Siemens SIMATIC RF650R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC RF650R and is the answer not in the manual?

Siemens SIMATIC RF650R Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC RF650R
CategoryOther
LanguageEnglish

Related product manuals