TC35i AT Command Set
8.6 AT^SMOND
s
m
obil
e
TC35i_ATC_V02.07 Page 195 of 439 1/30/04
Confidential / Released
Parameter Description
integer or sum of integers each representing a class of requested information, i.e. a group of output values.
parameter format can be determined by summing up the values for each of the requested classes of information.
The possible values and their associated information are listed below. Value 0 is not allowed. The default value
and the maximum value are 15, representing the sum of all possible class values, leading to the output of all
available information.
1 include
<sci> in response string <celldata>
2 include <nci> in response string <celldata>
4 include <TA> in response string <celldata>
8 include <rssiber> in response string <celldata>
display period
1...254 display period in seconds, i.e. the period to wait before the next output of
<celldata>.
a list of values describing the current radio environment of the module. The information to be included in the
response string can be selected using parameter
<format>. All values are comma-separated with no <CR> or
<LF> included in the response string.
possible groups of information are (in order of output):
<sci>, <nci>, <TA> and <rssiber>.
serving cell information (comma-separated, no cr/lf included)
<MCC>,<MNC>,<LAC>,<cell>,<BSIC>,<chann>,<RxLev>,<RxLev>Full,<RxLev>Sub,<RxQual>,<RxQual
>
Full,<RxQual>Sub,<Timeslot>
if no serving cell is found, unavailable values are omitted:" ,,,,,,<RxLev>,,,0,,,0"
neighbour cell information for neighbour cell 1 through 6 (comma-separated, no cr/lf included)
<MCC>
1
,<MNC>
1
,<LAC>
1
,<cell>
1
,<BSIC>
1
,<chann>
1
,<RxLev>
1
, (these parameters repeated for neighbour
cells 2 through 6 with no CR/LF): ...
<MCC>
6
,<MNC>
6
,<LAC>
6
,<cell>
6
,<BSIC>
6
,<chann>
6
,<RxLev>
6
an unavailable cell appears as follows: " ,,,,,,0"
Values for RSSI and BER (comma-separated, no cr/lf included)
<RSSI>,<BER>
Mobile country code
3 digits, e.g. 232
000 not decoded
<format>
(num)
<period>
(num)
<celldata>
(str)
<sci>
(str)
<nci>
(str)
<rssiber>
(str)
<MCC>
(num)

Table of Contents