TC35i AT Command Set
11.26 AT^SSCONF
s
m
obil
e
TC35i_ATC_V02.07 Page 322 of 439 1/30/04
Confidential / Released
display filler bits
[0]
(&F)
the mobile station shall display the filler bits
1 the mobile station shall not display the filler FF for statusreports at PDU mode
anymore (filler bits are network dependant).
Notes
• The parameters <ra> and <tora> appear in the result codes of the AT commands AT+CMGL, AT^SMGL,
AT+CMGR, AT^SMGR and the unsolicited result code "+CDS".
• Please note that the setting is stored volatile, i.e. after restart or reset, the default value 0 will be restored.
Also, there is no way to store
AT^SSCONF to the user defined profile.
• The parameter
<ff> appears in the result codes of the AT commands AT+CMGL, AT^SMGL, AT+CMGR,
AT^SMGR.
<ff>
(num)