5-14
3. Flange Back Adjustment
3-1. Flange Back Adjustment (1)
(Using Flange Back Adjustment Chart)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Mode Still (Auto ( ))
Subject Flange back adjustment chart
(2.0 m from the front of the protection
glass)
(Luminance: 350 ± 50 lux)
Measurement Point Display data of page: F, address: 87
Measuring Instrument Adjustment remote commander
Adjustment Page F
Adjustment Address 14 to 25, 87, 8A , 8B (MVC-CD200)
14 to 25, 87 to 9B (MVC-CD300)
Specified value 00
Note1: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Adjusting method:
Order Page
Address
Data Procedure
1 0 01 01 Set the data.
2 6 01 13 Set the data, and press PAUSE
button.
3 6 01 15 Set the data, and press PAUSE
button.
4 6 02 Check that the data changes to
“01”. (Note2)
5 F 87 Check that the data is “00”.
Note2: The adjustment data will be automatically input to the adjustment
addresses.
Processing after Completing Adjustments:
Order Page
Address
Data Procedure
1 6 01 00 Set the data, and press PAUSE
button.
2 0 01 00 Set the data.
3
Perform “Flange Back Adjustment
(2)”. (MVC-CD200)
Perform “Flange Back Check”.
(MVC-CD300)
3-2. Flange Back Adjustment (2)
(MVC-CD200)
Perform this adjustment after performing “Flange Back Adjustment
(1)”.
Mode Still (Auto ( ))
Subject Subject more than 500m away
(Subjects with clear contrast such as
buildings, etc.)
Measurement Point Check operation on TV monitor
Measuring Instrument
Adjustment Page F
Adjustment Address 14 to 25, 87, 8A , 8B
Note1: Make the lens horizontal and perform this adjustment.
Preparations:
1) Set the zoom lens to the TELE end and expose a subject that is
more than 500m away (subject with clear contrast such as
building, etc.). (Nearby subjects less than 500m away should
not be in the screen.)
Adjusting method:
Order Page
Address
Data Procedure
1 0 01 01 Set the data.
2 6 01 13 Set the data, and press PAUSE
button. (Note2)
Place a ND filter on the lens so that
the optimum image is obtained.
3 6 01 29 Set the data, and press PAUSE
button.
4 6 02 Check that the data changes to
“01”. (Note2)
Note2: The adjustment data will be automatically input to the adjustment
addresses.
Processing after Completing Adjustments:
Order Page
Address
Data Procedure
1 6 01 00 Set the data, and press PAUSE
button.
2 Perform “Flange Back Check”.