418 Parameters
74
74 ESP control
Enables ESP function parameters.
74.01 ESP control word Defines the control source for the primary ESP control
program functions.
By default, most of the ESP function enable parameters use
ESP control word as a source.
Note: If the user chooses to use different control source for a
certain function, this control word setting will have no effect
for that particular function.
74.20 Restart delay
enable
Defines the source for Restart delay function enable signal.
The restart delay function inhibits user start command for the
time set in parameter 74.21 Restart delay time.
For further information on Restart delay, see section Restart
delay (page 42).
ESP CW bit 1
Not selected Restart delay enable signal is disabled. 0
Selected Restart delay enable signal is enabled. 1
DI1 Digital input DI1 (10.02 DI delayed status, bit 0). 2
DI2 Digital input DI2 (10.02 DI delayed status, bit 1). 3
DI3 Digital input DI3 (10.02 DI delayed status, bit 2). 4
DI4 Digital input DI4 (10.02 DI delayed status, bit 3). 5
DI5 Digital input DI5 (10.02 DI delayed status, bit 4). 6
DI6 Digital input DI6 (10.02 DI delayed status, bit 5). 7
DIO1 Digital input/output DIO1 (11.02 DIO delayed status, bit 0). 8
DIO2 Digital input/output DIO2 (11.02 DIO delayed status, bit 1). 9
ESP CW bit 1 Parameter 74.01 ESP control word, bit-1 status controls
enable/disable status of the function.
10
Other [bit] Source selection (see Terms and abbreviations on page 148).
No. Name/Value Description Def/FbEq16
Bit Name Description
0 Reserved
1 Restart delay Enables restart delay function.
2 Backspin speed observer Enables backspin speed observer
function.
3 Reserved
4 Acceleration assistance Enables acceleration assistance function.
5 Kick start Enables kick-start function.
6 Current pulse start Enables current pulse start function.
7 Underload protection Enables underload protection function.
8 Overload protection Enables overload protection function.
9 Energy optimizer Enables energy optimizer function.
10 U/f voltage curve Enables U/f voltage curve function.
11 IR-compensation Enables IR-compensation.
12 Pump cleaning Enables pump cleaning function.
13 Reserved
14 Auto mode enable Enables auto mode enable function.
15 Time control Enables time control function.