Parameters 421
Other [bit] Source selection (see Terms and abbreviations on page 148).
74.80 Observer speed
measured
Displays the speed measured by the Backspin Speed
Observer function.
0.00
0.00...600.00 Hz Observer speed measured. 1 = 1Hz
74.99 ESP start/stop sw Displays status word of the functions controlling ESP specific
start/stop logic.
75
75 ESP reference setup
Controls frequency/speed reference settings of a drive.
See section Underload and overload protection (page 52).
75.11 Pump speed ref
source
Defines the source for the speed reference.
The unit (Hz or rpm) of the speed input is determined with
parameter 19.20 Scalar control reference unit.
Note: If the input reference has a custom scaling, then it
should be explicitly set with parameter 75.13 Speed reference
scaler.
Fixed speed
ref
NULL None 0
AI1 scaled 12.12 AI1 scaled value (see page 197). 1
AI2 scaled 12.22 AI2 scaled value (see page 199). 2
FBA1 ref 03.05 FB A reference 1 (see page 156). 3
FBA2 ref 03.06 FB A reference 2 (see page 156). 4
No. Name/Value Description Def/FbEq16
Bit Name Description
0 Restart delay Enabled Restart delay function is enabled.
1 Restart delay Active Restart delay function is active now.
2 Restart delay Done Restart delay function has been
completed.
3 Speed obs. Enabled Backspin speed observer function is
enabled.
4 Speed obs. Initializing Backspin speed observer function is
initializing.
5 Speed obs. Measuring Backspin speed observer function is now
measuring the actual speed.
6 Speed obs. In-range Backspin observer measured speed is
now is the user defined safe-speed range.
7 Speed obs. Speed check delay Backspin observer speed check delay
timer is on.
8 Speed obs. Ok to restart Backspin speed observer routine is over.
Motor speed is at safe-speed range.
9 Speed obs. Sleeping Backspin speed observer function routine
will be reinitialized on the next start
command.
10 Flying start speed check Enabled Flying start speed check is enabled.
11 Flying start speed check Done Flying start speed check has been
completed.
12 Flying start speed check OK Flying start speed check requested
bypassing of the starting routines.
13 Time control Enabled Time control function is enabled.
14 Time control OFF-state Time control function is in OFF state.
15 Time control ON-state Time control is in ON state.

Table of Contents

Other manuals for ABB ACS880-04XT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACS880-04XT and is the answer not in the manual?

ABB ACS880-04XT Specifications

General IconGeneral
BrandABB
ModelACS880-04XT
CategoryController
LanguageEnglish

Related product manuals