1D – 14IENGINE COOLING
DAEWOO V–121 BL4
5. Remove the surge tank attaching bolt.
6. Remove the surge tank from the support mount.
7. Clean the inside and the outside of the surge tank
and the surge tank cap with soap and water.
8. Rinse the surge tank and the cap thoroughly.
Installation Procedure
1. Install the surge tank to the support mount.
2. Secure the surge tank with the attaching bolt.
Tighten
Tighten the surge tank attaching bolt to 4 NSm (35
lbin).
3. Connect the return hose and the throttle body hose
to the top of the surge tank.
4. Connect the feed hose to the bottom of the surge
tank.
5. Secure the return hose, the throttle body hose, and
the feed hose to the surge tank with the hose
clamps.
6. Fill the surge tank with the coolant to the center
ridge, or to the MAX mark.