1) Click , and then draw a detection area on the video image. Right-click the image to
stop drawing.
2) Configure parameters.
Table 5-41 Parameters of people approach detection
Parameter Description
Name Customize the rule name.
Sensitivity Set alarm sensitivity.
Duration
Set how long two people stay in the same detection area until an
alarm is triggered.
Repeat Alarm Time
Set repeat alarm time. If the alarm-triggering event continues, an
alarm will be triggered again when repeat alarm time passed.
Interval Threshold
When the distance between people in the area is greater than or less
than the defined threshold, an alarm will be triggered.
3) Click
OK
.
Step 5 Configure alarm schedule and linkage.
Figure 5-159 Schedule and alarm linkage
1) Click .
2) Click
Setting
next to
Schedule
to configure the alarm period.
The system performs linkage actions only for alarms during the arming period.
●
On the time line, drag to set the period.
●
You can also click to set the period.
3) Configure alarm linkage. For details, see Table 5-50.
4) Click
Apply
.
Step 6 Click
Apply
.
5.9.8.2.2 Fall Detection
When someone falls from a height in the detection area and the duration of the action is greater
than the defined threshold, an alarm will be triggered.
Procedure
Step 1 Select
Main Menu
>
AI
>
Parameters
>
Stereo Analysis
.
Step 2 Select a channel and then click
Add
.