216 Script Commands
Reset Storage Array iSCSI Baseline
This command resets the iSCSI baseline for the storage array to 0.
Syntax
reset storageArray iscsiStatsBaseline
Parameters
None.
NOTE: This command resets the baseline to 0 for both RAID controller modules in
the storage array. The purpose of resetting both of the RAID controller module
baselines is to help ensure that the counts are synchronized between the RAID
controller modules. If one RAID controller module resets but the second RAID
controller module does not reset, the host is informed that the RAID controller
modules are out of synchronization. The host is informed by the time stamps that
are reported with the statistics.
Example
-c "reset storageArray iscsiStatsBaseline;"
Reset Storage Array SAS PHY Baseline
This command resets the SAS physical layer (PHY) baseline for all SAS
devices in a storage array.
Syntax
reset storageArray SASPHYBaseline
Parameters
None.
book.book Page 216 Wednesday, June 8, 2011 12:20 PM