Chapter 4 Operating ISPSoft
4-35
4_
4.6
Testing and Debugging a Program
4.6.1
Creating a Connection
Before a program and parameters are downloaded to a PLC or monitored online, ISPSoft must be connected to the PLC.
In this example, ISPSoft is connected to the CPU module AHxxEMC-5A through a USB cable. Please refer to section 3.2
for more information about connecting ISPSoft to a PLC in other ways. Please refer to operation manuals for more
information about wiring.
Those who have connected ISPSoft to a PLC successfully in accordance with the contents of section 3.2 can skip
this section.
(1) Install the modules on the main backplane in accordance with the hardware configuration in HWCONFIG. Make
sure that the wiring is correct, and then power the CPU module.
(2) Make sure that COMMGR is started, and the icon representing COMMGR is displayed on the system tray. If the
icon representing COMMGR is not displayed on the system tray, you can start COMMGR by clicking the shortcut on
the Start menu (Start>Programs>Delta Industrial Automation>Communication>COMMGR).
(3) Double-click the icon representing COMMGR on the system tray to open the COMMGR window. Click Add in the
COMMGR window to create a driver.

Table of Contents

Other manuals for Delta AH Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta AH Series and is the answer not in the manual?

Delta AH Series Specifications

General IconGeneral
BrandDelta
ModelAH Series
CategoryController
LanguageEnglish

Related product manuals