60
EMC Connectrix B Series v6.2 ED-DCX-4S-B Hardware Reference Manual
Log In and Configuration
Powering off the ED-DCX-4S-B
1. Shut down the ED-DCX-4S-B using the sysShutdown command.
switch::admin> sysshutdown
This command will shutdown the operating systems on
your switch.
You are required to power-cycle the switch in order to
restore operation.
Are you sure you want to shutdown the switch [y/n]?y
HA is disabled
Stopping blade 1
Shutting down the blade....
Stopping blade 2
Shutting down the blade....
Stopping blade 8
Shutting down the blade....
Broadcast message from root (pts/1) Tue Aug 23 14:23:06
2008...
The system is going down for system halt NOW !!
2. Power off the chassis by flipping the AC power switches on the
power supplies to “0” (LEDs inside AC power switches should
turn off). To maintain the ground connections, leave power cords
connected to the power supplies and to the electrical outlets.