EasyManuals Logo
Home>Hitachi>Printer>PXR

Hitachi PXR User Manual

Hitachi PXR
231 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #175 background imageLoading...
Page #175 background image
7-18
7.2.16 Heating Unit Sensor Fault
Heating Unit Sensor
Fault
Disconnect the EZJ94 board
CN7 connector and reconnect it.
Replace the heating unit.
Replace the EZJ94 board.
Resume the
operation.
Does the fault recur?
Does the fault recur?
Y
es
No
Clear the fault.
・From the maintenance screen,
place the heating unit in the
operating mode.
Restart the IJ printer.
Y
es
No
Replace the EZJ93 board.
Does the fault recur?
Y
es
No
- On detecting this fault, the IJ printer automatically sets the “Ink temperature
correction” to (disable).
“System environment setup Ink temperature correction (enable) Æ (disable)
After getting rid of the fault, reset the Ink temperature correction to (enable).
“System environment setup Ink temperature correction (disable) Æ (enable)
- In the condition of the “Ink temperature correction (disable),” the “Ink temperature
correction confirmation” message appears each time the power is turned on.
(See “1.2.7 Heating of Ink” in the Instruction manual”.)
Caution
!
Clear the fault.
・From the maintenance screen,
place the heating unit in the
operating mode.
Restart the IJ printer.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi PXR and is the answer not in the manual?

Hitachi PXR Specifications

General IconGeneral
BrandHitachi
ModelPXR
CategoryPrinter
LanguageEnglish

Related product manuals