7-18
7.2.16 Heating Unit Sensor Fault
Heating Unit Sensor
Fault
Disconnect the EZJ94 board
CN7 connector and reconnect it.
es
No
・Clear the fault.
・From the maintenance screen,
place the heating unit in the
operating mode.
・Restart the IJ printer.
es
No
- On detecting this fault, the IJ printer automatically sets the “Ink temperature
correction” to (disable).
“System environment setup Ink temperature correction (enable) Æ (disable)
After getting rid of the fault, reset the Ink temperature correction to (enable).
“System environment setup Ink temperature correction (disable) Æ (enable)
- In the condition of the “Ink temperature correction (disable),” the “Ink temperature
correction confirmation” message appears each time the power is turned on.
(See “1.2.7 Heating of Ink” in the Instruction manual”.)
Caution
!
・Clear the fault.
・From the maintenance screen,
place the heating unit in the
operating mode.
・Restart the IJ printer.